Standard Rectangular | Top Down and Top Down/Bottom Up | Night and Day
- Min. Mounting Depth, Flush Mount:
- Standard Installation
Bracket .................................3"
- Specialty End Mount
Bracket .................................3"
Outside Mount
- Min. Flat Vertical Surface:
- Standard Installation
Bracket ................................ 1"
Ordering Notes
- Follow basic measuring instructions.
- Specify left or right side lift cords.
- Inside Mounts: Specify standard installation brackets. Specialty end mount brackets may be used where conventional mounting techniques are not appropriate Ñ in arched window openings, for example.
- Outside Mounts: Specify extension brackets or spacer blocks, if required for additional clearance.
- Arch over standard shade: Specialty end mount brackets are used with inside mounts. Specialty wall mount brackets are used with outside mounts.
- Specify hold down brackets, if desired.
Standard Rectangular Shades fit rectangular window openings up to 144" wide. Maximum height varies with the width of the shade and the maximum drop of the fabric being used. Standard rectangular shades are cord-operated, and open from the bottom to the top.
Size Standards
- Min. Width ................................. 12"
- Max. Width ............................... 144"
- Max. Width, End Mount ................ 36"
- Max. Height (most fabrics) ......... 144"
-
- Except: ¾" Translucent ...... 192"
- Blackout................ 174"
- Maximum Recommended
Area (most fabrics) ................ 60ft²
-
- Except:Blackout ............... 40ft²
- Double Cell........... 30ft²
- For shades with increased square footage, see Heavy Duty Continuous Cord specifications; or for Standard Continuous Cord System, see Standard Continuous Cord specifications.
Mounting Requirements
7/16" Pleat
Inside Mount
- Min. Mounting Depth:
- Standard Installation Bracket.................................. 1"
- Min. Mounting Depth, Flush Mount:
- Standard Installation
Bracket ............................. 2 ½"
- Specialty End Mount
Bracket ............................. 2 ½"
Outside Mount
- Min. Flat Vertical Surface:
- Standard Installation
Bracket ................................ 1"
- Specialty End Mount
Bracket ................................ 1"
3/4" Pleat and Double Cell
Inside Mount
- Min. Mounting Depth:
- Standard Installation
Bracket ................................ 1"
back to top
Top-Down and Top-Down/Bottom-Up shades fit rectangular window openings up to 66" wide by 96" high. With top-down shades, the center rail is the moving rail and the shade opens from the top to the bottom. With top-down/bottom-up shades, both the center rail and bottom rail are moving rails, each with their own set of lift cords. The shade opens either from the top to the bottom or from the bottom to the top.
Ordering Notes
- Follow basic measuring instructions.
- Top-down: Specify left or right side lift cords.
- Top-down: Specify whether bottom rail is free-hanging or spring-anchored.
- Inside Mounts Specify standard installation brackets.
- Outside Mounts Specify extension brackets or spacer blocks, if required.
- Specify hold down brackets, if desired.
Size Standards
- Min. Width ................................. 12"
- Max. Width (most fabrics) ............ 66"
-
- Except: Double Cell ............. 60"
- Max. Width, End Mount ................ 36"
- Maximum Height (most fabrics) .... 96"
-
- Except: Double Cell ............. 90"
- Max. Area (most fabrics) ........... 44ft²
-
- Except: Blackout................ 40ft²
- Double Cell ........... 37ft²
Mounting Requirments
Same as standard rectangular (see above)
back to top
Night and Day Shades fit rectangular window openings up to 72" wide by 96" high. Two fabric panels are used, one between the headrail and center rail, and one between the center rail and bottom rail. Both the center rail and bottom rail are moving rails, each with their own set of lift cords. Either fabric panel, or portion of a fabric panel, may be used to cover the window.
Night and Day shade has the choice of two window coverings for the same window. Typically, translucent fabric is used for the top panel and opaque, or blackout, fabric is used for the bottom panel. Double Cell fabric may also be used in combination with a ¾" pleat fabric.
Size Standards
- Min. Width ................................. 12"
- Max. Width (most fabrics) ............ 72"
-
- Except: Double Cell ............. 60"
- Max. Width, End Mount ................ 36"
- Maximum Height (most fabrics) .... 96"
-
- Except: Double Cell ............. 90"
- Max. Area per fabric panel (most fabrics) ...................................... 48"
-
- Except: Blackout................ 40ft²
- Double Cell ........... 30ft²
Mounting Requirments
Same as standard rectangular (see above)
Ordering Notes
- Follow basic measuring instructions.
- On the order form, list the top fabric panel first and the bottom fabric panel second.
- Inside Mounts Specify standard
installation brackets.
- Outside Mounts Specify extension
brackets or spacer blocks, if required.
- Specify hold down brackets, if desired.
back to top